KM - Install loadable driver
Overview of product lines
Product lines | Models |
Thames | C353, C253, C203 |
Mosel | C650, C550, C451 |
Donau | C652, C552, C452 |
GangesM | 501, 421, 361 |
Amur | C360, C280, C220 |
Taiga | 423, 363, 283, 223 |
LaplataM | 751, 601 |
Citrine | C35, MF30-1 |
TaigaY | bizhub 42, bizhub 36, MF42-1, MF36-1 |
Minerva | C754, C654 |
Zeus | C554, C454, C364, C284, C224 |
Symphony | PRESS1250, PRESS1250P, PRESS1052, PRO951 |
Thames\Mosel devices
Model | Thames vs. Mosel |
C353 | Thames 1(ti1) |
C253 | Thames 2(ti2) |
C203 | Thames 2.5(ti2_5) |
C650 | Mosel 1(mi1) |
C550 | Mosel 2(mi2) |
C451 | Mosel 3(mi3) |
Thames/Mosel
Insert CF card (max 256 MB).
Extract Thames/Mosel archive with drivers to disk.
Go to the directory according to the device code name.
Run command mkcfldr.bat (device code) (CF drive letter) - for example mkcfldr.bat mi2 e:
Turn off the MFD.
Insert the CF card in MFD.
Turn on the MFD.
Wait for driver download.
Turn off the MFD and remove the card.
Turn on the MFD.
Go to service mode and choose.
Set authentication device > CARD2.
GangesM/LaplataM
Copy LoadableDeviceDriverROM directory to the root of USB flash disk.
Insert the flash disk to the MFD.
Enter the Service Mode.
Press the System 2 in Service mode screen.
Press ISW.
Press the Board Type Selection.
Select Loadable Device Driver and press OK.
Press the File Selection.
Select the relevant firmware version and press OK.
Press Execute.
Press Start.
Check to see the message ISW was completed.
Amur
Copy A0EDFW.tar to the root directory of a USB flash drive.
Insert the USB flash drive into the USB port at the rear side of the main body.
Turn on the main switch.
Select YES and touch the START button displayed on the panel.
When the downloading process was finished, the message of Download Complete comes out on the panel.
Turn off the main switch and remove the USB flash drive.
Donau
Copy A0P0FW.tar to the root directory of a USB flash drive.
Insert the USB flash drive into the USB port for service at the rear side of the main body. (Remove the screw and lift up the cover of the USB port)
Turn on the main switch.
Select YES and touch the START button displayed on the panel.
When the downloading process was finished, the message of Download Complete comes out on the panel.
Turn off the main switch and remove the USB flash drive.
Taiga
Copy A1UDFW.tar to the root directory of a USB flash drive.
Insert the USB flash drive into the USB port for service at the rear side of the main body. (Remove the screw and lift up the cover of the USB port)
Turn on the main switch.
Select YES and touch the START button displayed on the panel.
When the downloading process was finished, the message of Download Complete comes out on the panel.
Turn off the main switch and remove the USB flash drive.